tencent cloud

피드백

Troubleshooting earlier LogListener versions

마지막 업데이트 시간:2024-01-20 17:55:44
    Note:
    This document provides troubleshooting information for LogListener 2.2.4 and earlier. For information on troubleshooting the latest version, see Server Group Exceptions.

    Error Description

    An exception occurred with log collection, and the associated server group is found to be exceptional.

    Possible Causes

    The heartbeat between the server group and the CLS system is interrupted, resulting in failure to collect and report logs. Possible causes for the server group exception include:
    1. The IP address is incorrect.
    2. The network is disconnected.
    3. LogListener process failure.
    4. LogListener is configured incorrectly.

    Solution

    Troubleshoot problems according to the above causes.

    Directions

    1. Check whether the IP address added to the server group is correct.
    1.1 Check the IP address obtained by LogListener by running the following command:
    cd loglistener/tools && ./check.sh
    
    image
    
    
    1.2 Log in to the Cloud Log Service Console, and click Server Group in the leftside bar. On the Server Group Management page, check the IP address of the server group. The IP address must be the same as that for collection.
    2. Check whether the network is connected by running the following command:
    telnet <region>.cls.myqcloud.com 80
    <region> is the abbreviation for the region where CLS resides. For more information on regions, see Available Regions. The following code appears upon normal network connection. Otherwise, connection fails. Check the network and ensure normal connection.
    
    
    3. Check whether LogListener processes are running normally. Go to the installation directory and run the following command:
    cd loglistener/tools && ./p.sh
    Normally, there are three processes:
    bin/loglistenerm -d #Daemon process
    bin/loglistener --conf=etc/loglistener.conf #Main process
    bin/loglisteneru -u --conf=etc/loglistener.conf #Update process
    If any process fails, restart it. Go to the installation directory and run the following command:
    cd loglistener/tools && ./start.sh
    4. Check whether the key and IP address are correctly configured in LogListener. Go to the installation directory to check the configuration information by running the following command:
    cd loglistener/etc && cat loglistener.conf
    See the following figure:
    
    
    The key is the API key for the Tencent Cloud account or the collaborator. Project keys are not supported.
    group_ip in the configuration file must be consistent with the IP address entered in the server group on the console. Since LogListener obtains the server IP address automatically, check the consistency regularly when the server is bound to multiple ENIs.
    문의하기

    고객의 업무에 전용 서비스를 제공해드립니다.

    기술 지원

    더 많은 도움이 필요하시면, 티켓을 통해 연락 바랍니다. 티켓 서비스는 연중무휴 24시간 제공됩니다.

    연중무휴 24시간 전화 지원