Use Cases
You can mount a CFS Turbo storage for a TKE Serverless. The add-on is used to mount the Tencent Cloud CFS Turbo file system to a workload based on a private protocol. Currently, only static configuration is supported. For more information about CFS storage types, see Storage Types and Performance. Prerequisites
A TKE Serverless of v1.14 or later has been created.
Directions
Creating a file system
Note
After the file system is created, you need to associate the cluster network (vpc-xx) with the CCN instance of the file system. You can check it in the information about file system mount target. Deploying a Node Plugin
Step 1. Create a csidriver.yaml file
Here is an example of a csidriver.yaml file:
apiVersion: storage.k8s.io/v1
kind: CSIDriver
metadata:
name: com.tencent.cloud.csi.cfsturbo
spec:
attachRequired: false
podInfoOnMount: false
Step 2. Create a CSI driver
Run the following command to create a CSI driver:
kubectl apply -f csidriver.yaml
Creating a CFS Turbo volume
Step 1. Create a CFS Turbo type PV based on the following template
apiVersion: v1
kind: PersistentVolume
metadata:
name: pv-cfsturbo
spec:
accessModes:
- ReadWriteMany
capacity:
storage: 10Gi
csi:
driver: com.tencent.cloud.csi.cfsturbo
volumeHandle: pv-cfsturbo
volumeAttributes:
host: *.*.*.*
fsid: ********
path: /
storageClassName: ""
metadata.name: The name of the created PV.
spec.csi.volumeHandle: It must be consistent with the PV name.
spec.csi.volumeAttributes.host: The IP address of the file system. You can check it in the file system mount target information.
spec.csi.volumeAttributes.fsid: The fsid of the file system (not the file system ID). You can check it in the file system mount target information. It is the string between tcp0:/
and /cfs
in the mount command, as shown in the following figure.
spec.csi.volumeAttributes.path: The subdirectory of the file system. /
is entered if it is left empty (to improve the mounting performance, /
is located under the /cfs
directory). If you want to specify a subdirectory for mounting, you must ensure that the subdirectory exists in /cfs
in the file system. The workload cannot access the parent directory of the subdirectory after mounting. For example, for path: /test
, you must ensure that the /cfs/test
exists in the file system.
Step 2. Create a PVC that is bound to the PV based on the following template
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: pvc-cfsturbo
spec:
storageClassName: ""
volumeName: pv-cfsturbo
accessModes:
- ReadWriteMany
resources:
requests:
storage: 10Gi
Parameters:
metadata.name: The name of the created PVC.
spec.volumeName: It must be consistent with the name of the PV created in Step 1. Using a CFS Turbo volume
Create a Pod that mounts the PVC based on the following template.
apiVersion: v1
kind: Pod
metadata:
name: nginx
spec:
containers:
- image: ccr.ccs.tencentyun.com/qcloud/nginx:1.9
imagePullPolicy: Always
name: nginx
ports:
- containerPort: 80
protocol: TCP
volumeMounts:
- mountPath: /var/www
name: data
volumes:
- name: data
persistentVolumeClaim:
claimName: pvc-cfsturbo
Apakah halaman ini membantu?